Accessory
Amlifiers
Analyzers
Attenuators
Audio/Video Instruments
Calibration standard
Counter
EMI/EMS/Safty Tester
Generators
Meters
Optical Instruments
Oscilloscopes
Power Supplies
Probes
Recorder/Data logger
Telecommunication Instruments
Testers
Wireless/Mobile Instruments
Semiconductors
Repair Parts
Mannuals
Etc.
ÀÌÈ­Çкм®±â
   (Physico-Chemistry Analyzer)
¾Ç¼¼»ç¸® Á÷°Å·¡ ÀåÅÍ
 
 
 
 
 
EMI/EMS/Safty Tester > Surge Simulators : NSG2050
NSG2050
»óÇ°¸í : Surge Simulators
¸ðµ¨¸í : NSG2050
¸ÞÀÌÄ¿ : Schaffner
ÀϷùøÈ£ :
½ÅÇ°/Áß°í/·»Å»¿©ºÎ :
°Å·¡Á¶°Ç :
ÁöºÒÁ¶°Ç :
½ÅÇ°ÆǸŰ¡°Ý :
Áß°íÆǸŰ¡°Ý : call
·»Å»°¡°Ý : call
 
»ó¼¼½ºÆå

Teseq (Schaffner) NSG 2050 High Energy Pulse Generator System
PNW2050/CDN133/WIN2050

The Teseq (Schaffner) NSG 2050 High Energy Pulse Generator System is intended for executing interference immunity tests with surge pulses as called for in IEC 801-5 and various derivatives such as IEC 1000-4-5, EN 55101-5, IEC 384-14, ANSI/IEEE C62.41, CCITT, FCC Part 68, Bellcore TR-NWT-001089, etc.

Specifications
Pulse Voltage 6.6 kV max
Repetition Rate Depends on the PNW
Phase positioning Synchronous from 0 - 359¡Æ or asynchronous
Polarity Positive, negative or alternating
Internal Impedance Depends on the PNW
Pulse Rise Time Depends on the PNW
Pulse Width Depends on the PNW
Remote Control Input RS 232 port on the rear panel

¿É¼Ç»çÇ×

Pulse Networks, PNW
PNW2050 (installed in top unit)

Produces the following pulses to satisfy the requirements of the standards: IEC 1000-4-5 (IEC801-5) / EN 61000-4-5 / IEEE C62.41 / IEEE 587 / etc.
Hybrid Pulse 1.2/50 ¥ìs (open-circuit) 200 V to 6.6 kV; 8/20 ¥ìs (short-circuit) at up to 3.3 kA
Pulse Form 1.2/50 ¥ìs (open-circuit); 8/20 ¥ìs (short-circuit into 2 ohms impedance)
Voltage 200 V to 6600 V adjustable in 10 V steps
Short-Circuit Current 100 A to 3300 A into 2 ohms impedance; 16.6 A to 550 A into 12 ohms impedance
Impedance 2 ohms, 12 ohms
Polarity P (positive), N (negative), A (alternating)
Pulse Outputs Earth-free (floating)
Repetition 10 s to 10000 s
Number of pulses 1 to 9999

Teseq CDN133 3 Phase Coupling Network
The Teseq CDN133 is a 3-Phase Coupling Network for EUT`s up to 440V/30A per phase. It is intended for use with Surge Generators: NSG 650, NSG 651 and NSG 2050.
Instrument Supply 115V / 230V ac nominal
EUT supply
(three phase)
AC voltage: 24 - 440V (phase to phase
DC voltage: 1 - 50V
Current: 25A continuous 30A for 30 mins
Coupling / decoupling elements to IEC 61000-4-5
Coupling modes all differential / all common mode / lines to GND
Burst coupling option
(optional)
AC voltage: 24 - 440V (phase to phase)
DC voltage: 1 - 50V
Current: 25A continuous 30A for 30 mins
Coupling / decoupling elements to IEC 61000-4-4
Coupling modes lines to ref. GND all combinations of lines to ref. GND

WIN2050