EMI/EMS/Safty Tester > ESD Simulators : SKS-1132GTB
SKS-1132GTB
»óÇ°¸í : ESD Simulators
¸ðµ¨¸í : SKS-1132GTB
¸ÞÀÌÄ¿ : SANKI
ÀϷùøÈ£ :
½ÅÇ°/Áß°í/·»Å»¿©ºÎ :
°Å·¡Á¶°Ç :
ÁöºÒÁ¶°Ç :
½ÅÇ°ÆǸŰ¡°Ý : call
Áß°íÆǸŰ¡°Ý :
·»Å»°¡°Ý :
 
»ó¼¼½ºÆå

Frequency drop simulator GTB

 

SKS-1132GTB

Features:
1) fully meet the IEC61000-4-11 and GB / T17626.11 standards; 
2) single-phase drop, drop-by-phase, three-phase synchronous drop, drop the line vector; 
3) 7-inch color LCD touch screen, a friendly man-machine interface, a higher degree of intelligence, accompanied by falling waveform graphic display, intuitive and easy to set up, high intelligence, more humane operation; 
4) rated current up to 20A (can be customized SKS-1132GTB, currents up to 32A). 

Technical Parameters:

Model  SKS-1132GTB
In line with capacity

Three-phase 380V32A

Voltage drop

0 ~ 265V ± 10% (1V steps), each with independent settings.
Three-way voltage drop may be different, you can simulate phase imbalance.

Fall ( rise ) starting phase

0 ~ 359 ° (1 ° step ) , each with independent settings.

Fall ( rise ) termination phase 0 ~ 359 ° (1 ° step ) , each with independent settings.
Trigger Mode Count Press the fall (rise ) cycle count set value, set independently for each phase.
50ms Every fall ( rise ) cycle contains three fall ( rise ), these three fall ( rise ) in the interval of50ms
Drop choice By-phase / multi-phase independent / multi-phase synchronization variety of combinations 
Fall ( rise ) continuous cycle number 1 to 50,000 cycles ( 1 cycle step a), each phase independently set
Fall ( rise ) interval cycle number 0000 to 50000 points cycles ( 1 cycle step a), each with independent settings
Fall (rise) cycles 1 to 50,000 cycles ( cycle step a)
Automatic determination of phase sequence Three-phase can be any connection, automatic determination of phase sequence
Touch screen graphical input Numeric Keypad

Synchronous display voltage /current / frequency

Overcurrent protection
Use of the environment Ambient temperature: 10 ~ 35 ° C   Relative humidity: 30% to 60%
power supply Single-phase AC220V ± 10 %, 50 / 60Hz
Weight About 200  kg

¿É¼Ç»çÇ×