»ó¼¼½ºÆå Single Phase - Power Analyzer

Voltage: Range
950Vpk, 400Vpk or 1500Vpk (see ordering information)

Internal Current: Range
8Apk, 40Apk (see ordering information)

External Current Transducers (Options E or I only)
Current: Current
Current: 10Arms for 50ms, 2.5Arms continuous, 5Apk measurable
Scaling (In=Out) = +0000.00A = 00.0000A through +\-9999.99A = 9999.99A
Current: Voltage
Voltage: 25Vpk for 50ms, 2.5Vrms continuous, 2.5Vpk measurable
Scaling (In=Out) = +0000.00V = 00.0000V through +\-9999.99V = 9999.99V

Resolution
0.05% of range

Voltage & Current Accuracy
(See chart to the left)

Frequency Measurement
20 mHz to 80 kHz, 0.01%

Crest Factor
Range: 1 to 999
Accuracy: from peak results

Harmonic & Spectrum Analysis
Frequency Range: 20 mHz to 50 kHz
Typical THD, harmonic and phase accuracy at line frequencies of 50/60 Hz:
THD accuracy: 0.1%
Harmonic accuracy: 0.05%
Phase accuracy: 0.1¨¬

Waveforms
Actual, Peak Capture, Distortion content and Glitch Capture

History
V&A (rms, peak, envelope, THD),Watts, VAR, PF
User-selectable time base from 400 msec/div to 1 day/div
Resolution 1/20 division

Physical
Power input: 80-265 VRMS autoselect, 40 - 400 Hz @ 25 VA max
Size: (HxWxD) 4-1/2¡±x 11-1/2¡±x 10-1/2¡±
Weight: 6 lbs (2.7 kg)
Operating range: 0¨¬C to 45¨¬C, <85% RH @ 40¨¬C non-condensing
Storage range: -30¨¬C to 65¨¬C <95% RH @ 40¨¬C non-condensing

Digital Interfaces (standard)
IEEE488.1: Full talk/listen capabilities
Parallel Printer: IEEE1284, unformatted text or PCL compatible
¿É¼Ç»çÇ×
÷ºÎÆÄÀÏ 2551_ds10_4.pdf